mode of operation of impact agitation tank. ... for domestic purpose it will be 240 V.P = 440 x 400 x 0.85 = 149600 watts = 149.6 KW.For commercial it will be 3 phase supply, so P = 1.732 x 149.6 = 259.1 Kwatts.For commercial purpose, 1 unit costs about Rs. 9/- i.e., 2331.9 /- .So for 150 TR the consumption is 2331.9 /-.And along with this you
[email protected]tm.comRainwater tanks. - Homogenisation of sludge with high concentration of solids. - Sewage plants and industrial facilities. - Washing trucks. Technical data - Sealed and encased motor. - 3-blade stainless steel propeller. - Propeller diameter of 400 mm. - 2 and 4 kW motor at 400 V/50 Hz. - Maximum agitation flow of 1,000 m3/h at 750 rpm in the
Get PriceAgitator tanks are fabricated from steel or 304 grade stainless steel. Tanks are available in capacities ranging from 5 gal. to 750 gal. Features include digital or analog temperature controls, variable agitation speeds, electrically heated valve, multiple circuit & blanket type heating. Tanks
Get PriceBiogas. Stamo’s top mounted agitators are individually designed and manufactured to meet the customer’s process requirements. A wide range of configuration alternatives cover all types of agitator needs. Stamo’s side mounted agitators are particularly useful when the tank’s design only allows access from the side
Get PriceInstalled power 11 kW, 14.75 Hp 4 kW, 5.36 Hp Power draw 6.4 kW 3.5 kW Energy consumption 42,048 kWh 22,995 kWh Comparison of a traditional agitator installation with Alfa Laval’s modern ALS A gitator installation (based on 18 hours of operation daily): Annual savings for electrical power (at €0.07 per kWh) = € 1,334 or
Get Priceof most batch liquid agitation systems. Standard propellers have three blades, but can be two-bladed, four-bladed, or encased by a circular guard. A revolving propeller traces out a helix in the fluid. One full revolution moves the liquid a fixed distance. The ratio of this distance to the propeller diameter is known as the pitch
Get Price0.203 m. It is used in a tank with a diameter of 0.61 m and height of 0.61 m. The width is W = 0.0405 m. Four baffles are used with a width of 0.051 m. The turbine operates at 275 rpm in a liquid having a density of 909 kg/m3 and viscosity of 0.02 Pas. Calculate the kW power of the turbine and kW/m3 of volume. Scale
Get PriceCourse Material Process Engineering: Agitation & Mixing Prepared By Anchor Institute _ Dharamsinh Desai University, Nadiad, Gujarat, India Page 7 Chapter 1. MIXING AND AGITATION Agitation is a means whereby mixing of phases can be accomplished and by which mass and heat transfer can be enhanced between phases or with external surfaces
Get Pricewater into and out of a storage tank at a low velocity to minimize mixing. The figure of merit (FOM) is a measure of a tank’s ability to maintain such sep a - ration; it indicates the effective percen t-age of the total volume that will be available to provide usable cooling. Well-designed stratified tanks
Get PriceJan 03, 2019 Pumping Rate: The rate at which the Bulk mass gets Pumped inside the Stirred tank, this is partially depends on the HotSpots of the Stirred Tank and the utility in the Jacket of the stirred tank. Scale of Agitation : Scale of Agitation gives the Intensity of Agitation or Mixing, Generally the Scale of Agitation
Get Priceb) the dimensions of the tank in meters for a tank with equal length, width, and depth, c) the power input required for a G of 900 sec-1 for a water temperature of 10 oC – express the answer in kW Answer: a) the quantity of alum needed on a daily basis in kg/d, = I K Q J P L 3 3.8 T10 7 I 7 @ 30 I C . 1 10 : I C 1000 I 7 ` L114
Get PriceStamo’s side mounted agitators are particularly useful when the tank’s design only allows access from the side. The side mounted agitators are also used to establish extra powerful agitation in the bottom area of the tank when it is needed. Output: 1.0 – 300 kW ... – Support to minimise the impact on the tank
Get Priceno.2 Slurry tank Degree of Agitation: Degree of agitation is the guide line for optimizing the rate of suspension of solids which ranges from 1 to 10. For vigorous agitation in any vessel/tank the calculated degree of agitation may work out to more than 10 but it is considered as equal to 10 only. Degree of agitation = Bulk fluid Velocity/6
Get PriceTank capacity= (π*10.22*9.2) / 4 :: (m2* m) Drive motor rating: = FOS * P/ (0.80) Tank capacity = 751.3769 m3 = 1.5 * 77.17583/ (0.80*0.95) = 144.7047 hp = 144.7047* 746 = 107.9497 Kw Tank Turnover Rate : Thus the drive motor of about 110 kW shall be adequate Tank turnover rate is the guideline figure to
Get Pricefurnace, constant temperature bath tank and variable agitation unit [16-20]. The constant temperature bath tank heated and maintained 12 liters of distilled water while the agitation was induced via a 2.5-inch diameter impeller located on one side of the quench tank. The impeller forced fluid to flow from one side of the tank
Get PriceFOB Price: US $ 8000-50000 / Piece. Min. Order: 1 Piece. Type: Mechanical Agitating Tank. Motor Power: 2.2kw. Mining Object: Ore. Motor Type: AC Motor. Impeller Type: Double Impeller. Certification: ISO. Suppliers with verified business licenses
Get Price